Tile Division
ASPECT CONCRETE REPRODUCTION TILES
DESCRIPTION OVERALL SIZE MIN.
PITCH
MAX.
PITCH
MIN.
HEADLAP
MAX.
HEADLAP
MIN.
GAUGE
MAX.
GAUGE
COVER
PER M²
WEIGHT
(tons)
per 1000
BATTEN
REQ'D
BATTEN
SIZE
(mm)
REDLAND DELTA 430x380mm 17.5° 44° 75mm 125mm 305mm 355mm 8.2 7 2.82m/m² 25x50
REDLAND 52 420x280mm 30° n/a 75mm n/a n/a 345mm 11.6 3.8 2.9m/m² 25x50
REDLAND 51 380x230mm 33.3° n/a 75mm n/a n/a 305mm 16 3 3.3m/m² 25x50
REDLAND CALEDONIAN 430x382mm 22.5° n/a 75mm (100mm<30°) n/a n/a 355mm
(330mm<30°)
7.9 5.5 2.82m/m² 25x50
REDLAND STATESMAN 400x275mm 30° n/a 75mm n/a n/a 316mm 13.7 3 n/a 25x50
REDLAND STONEWOLD MK1 430x380mm 17.5° 44° 75mm 125mm 305mm 355mm 8.2 6.24 2.82m/m² 25x50
ESSEX CHILTERN 432x315mm 17.5° n/a 75mm n/a n/a 330mm Approx
11.6
Approx
5
2.9m/m² 25x50
ESSEX DURO 380x230mm 22.5° n/a 75mm (100mm<25°) n/a n/a 305mm
(280mm<25°)
Approx
16
Approx
3.5
3.3m/m² 25x50
ANCHOR ANCONA 430X382mm 30° n/a 75mm n/a n/a Approx
340mm
Approx
12
Approx
3
3m/m² 25x50
BRIDGWATER D/ROMANS
D1 STRAIGHT BOND 368x273mm 35° n/a 75mm n/a n/a 241mm 14 3.6 n/a 25x50
D7 STRAIGHT BOND 419x343mm 35° n/a 75mm n/a n/a 311mm 9.1 4.8 n/a 25x50
D14 STRAIGHT BOND 419x356mm 30° n/a 75mm n/a n/a 311mm 9.1 5.5 n/a 25x50
R1 (REYNARDO) STRAIGHT BOND 419x356mm 30° n/a 75mm n/a n/a 311mm 9.1 5.9 n/a 25x50
D11 CROSS BOND 419x343mm 30° n/a 75mm n/a n/a 311mm 9.7 5.5 n/a 25x50
D12 CROSS BOND 419x356mm 30° n/a 75mm n/a n/a 311mm 9.7 5.9 n/a 25x50
THE ABOVE REPRODUCTION TILES ARE AVAILABLE IN MOST OF THE ORIGINAL COLOURS